Camera speed / F-stop Control
This unit automatically adjusts aperture to a programmed change of shooting speed. It is designed to
be used with the Arriflex, Aaton, and Panavision cameras.
Specifications:
F-stop changes automatically, following the change of the camera's speed
2 channels camera speed decimal settings: 1fps - 99fps (crystal)
Decimal F-stop setting
Power requirement: 12 or 24 V DC
Power consumption: 1W (12 V DC) - Motor Stop, 6W - Motor Run
Weight: 350g
Body: extruded aluminum
Finish: textured black
Indicators and Connectors:
Led power indicator: lights when power is applied to the unit by camera.
Remote input - 4 pin Lemo.
Camera 8 pin Lemo: to camera accessories connector.
Motor 5 pin Lemo: to Heden M26P motor.
M.Dir red toggle switch: reverses motor direction.
Led motor indicator: green light - forward, red light - reverse.
Channel 1 input: starting camera speed in fps.
Channel 2 input: ending camera speed in fps.
Use channel 1 and 2 to select the desired starting and ending camera speed. The larger the
difference of camera speeds between channel 1 and 2 with the same scale the longer the angle of
motor rotation will be. This is appropriate to the camera speed and F-stop correlation.
Blue toggle switch: to manually switch from channel 1 to 2.
Ramp: length of time the transition will take from camera speed 1/camera speed 2.
Offset input: changes the starting position of the servo motor.
Scale input: controls the length of motor travel.